Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Curr Osteoporos Rep ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652430

RESUMEN

PURPOSE OF REVIEW: This review aims to provide a theoretical basis and insights for quercetin's clinical application in the prevention and treatment of osteoporosis (OP), analyzing its roles in bone formation promotion, bone resorption inhibition, anti-inflammation, antioxidant effects, and potential mechanisms. RECENT FINDINGS: OP, a prevalent bone disorder, is marked by reduced bone mineral density and impaired bone architecture, elevating the risk of fractures in patients. The primary approach to OP management is pharmacotherapy, with quercetin, a phytochemical compound, emerging as a focus of recent interest. This natural flavonoid exerts regulatory effects on bone marrow mesenchymal stem cells, osteoblasts, and osteoclasts and promotes bone health and metabolic equilibrium via anti-inflammatory and antioxidative pathways. Although quercetin has demonstrated significant potential in regulating bone metabolism, there is a need for further high-quality clinical studies focused on medicinal quercetin.

2.
J Cereb Blood Flow Metab ; : 271678X241240582, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38489769

RESUMEN

Vascular pathology is the second leading cause of cognitive impairment and represents a major contributing factor in mixed dementia. However, biomarkers for vascular cognitive impairment and dementia (VCID) are under-developed. Here we aimed to investigate the potential role of CO2 Cerebrovascular Reactivity (CVR) measured with phase-contrast quantitative flow MRI in cognitive impairment and dementia. Forty-five (69 ± 7 years) impaired (37 mild-cognitive-impairment and 8 mild-dementia by syndromic diagnosis) and 22 cognitively-healthy-control (HC) participants were recruited and scanned on a 3 T MRI. Biomarkers of AD pathology were measured in cerebrospinal fluid. We found that CBF-CVR was lower (p = 0.027) in the impaired (mean±SE, 3.70 ± 0.15%/mmHg) relative to HC (4.28 ± 0.21%/mmHg). After adjusting for AD pathological markers (Aß42/40, total tau, and Aß42/p-tau181), higher CBF-CVR was associated with better cognitive performance, including Montreal Cognitive Assessment, MoCA (p = 0.001), composite cognitive score (p = 0.047), and language (p = 0.004). Higher CBF-CVR was also associated with better physical function, including gait-speed (p = 0.006) and time for five chair-stands (p = 0.049). CBF-CVR was additionally related to the Clinical-Dementia-Rating, CDR, including global CDR (p = 0.026) and CDR Sum-of-Boxes (p = 0.015). CBF-CVR was inversely associated with hemoglobin A1C level (p = 0.017). In summary, CBF-CVR measured with phase-contrast MRI shows associations with cognitive performance, physical function, and disease-severity, independent of AD pathological markers.

3.
Magn Reson Med ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38523598

RESUMEN

PURPOSE: Non-invasive measurement of cerebral venous oxygenation (Yv) is of critical importance in brain diseases. The present work proposed a fast method to quantify regional Yv map for both large and small veins. METHODS: A new sequence was developed, referred to as TRU-VERA (T2 relaxation under velocity encoding and rapid acquisition, which isolates blood spins from static tissue with velocity-encoding preparation, modulates the T2 weighting of venous signal with T2-preparation and utilizes a bSSFP readout to achieve fast acquisition with high resolution. The sequence was first optimized to achieve best sensitivity for both large and small veins, and then validated with TRUST (T2 relaxation under spin tagging), TRUPC (T2 relaxation under phase contrast), and accelerated TRUPC MRI. Regional difference of Yv was evaluated, and test-retest reproducibility was examined. RESULTS: Optimal Venc was determined to be 3 cm/s, while recovery time and balanced SSFP flip angle within reasonable range had minimal effect on SNR efficiency. Venous T2 measured with TRU-VERA was highly correlated with T2 from TRUST (R2 = 0.90), and a conversion equation was established for further calibration to Yv. TRU-VERA sequences showed consistent Yv estimation with TRUPC (R2 = 0.64) and accelerated TRUPC (R2 = 0.79). Coefficient of variation was 0.84% for large veins and 2.49% for small veins, suggesting an excellent test-retest reproducibility. CONCLUSION: The proposed TRU-VERA sequence is a promising method for vessel-specific oxygenation assessment.

4.
Magn Reson Med ; 91(5): 1787-1802, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37811778

RESUMEN

PURPOSE: To create an inventory of image processing pipelines of arterial spin labeling (ASL) and list their main features, and to evaluate the capability, flexibility, and ease of use of publicly available pipelines to guide novice ASL users in selecting their optimal pipeline. METHODS: Developers self-assessed their pipelines using a questionnaire developed by the Task Force 1.1 of the ISMRM Open Science Initiative for Perfusion Imaging. Additionally, each publicly available pipeline was evaluated by two independent testers with basic ASL experience using a scoring system created for this purpose. RESULTS: The developers of 21 pipelines filled the questionnaire. Most pipelines are free for noncommercial use (n = 18) and work with the standard NIfTI (Neuroimaging Informatics Technology Initiative) data format (n = 15). All pipelines can process standard 3D single postlabeling delay pseudo-continuous ASL images and primarily differ in their support of advanced sequences and features. The publicly available pipelines (n = 9) were included in the independent testing, all of them being free for noncommercial use. The pipelines, in general, provided a trade-off between ease of use and flexibility for configuring advanced processing options. CONCLUSION: Although most ASL pipelines can process the common ASL data types, only some (namely, ASLPrep, ASLtbx, BASIL/Quantiphyse, ExploreASL, and MRICloud) are well-documented, publicly available, support multiple ASL types, have a user-friendly interface, and can provide a useful starting point for ASL processing. The choice of an optimal pipeline should be driven by specific data to be processed and user experience, and can be guided by the information provided in this ASL inventory.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Marcadores de Spin , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Arterias , Imagen de Perfusión , Circulación Cerebrovascular , Imagen por Resonancia Magnética/métodos , Perfusión
5.
J Magn Reson Imaging ; 59(5): 1523-1541, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37819198

RESUMEN

The glymphatic system, which facilitates cerebrospinal fluid (CSF) flow through the brain parenchyma, is important for brain development and waste clearance. Advances in imaging techniques, particularly magnetic resonance imaging, have make it possible to evaluate glymphatic structures and functions in vivo. Recently, several studies have focused on the development and alterations of the glymphatic system in pediatric disorders. This review discusses the development of the glymphatic system, advances of imaging techniques and their applications in pediatric disorders. First, the results of the reviewed studies indicate that the development of the glymphatic system is a long-lasting process that continues into adulthood. Second, there is a need for improved glymphatic imaging techniques that are non-invasive and fast to improve suitability for pediatric applications, as some of existing methods use contrast injection and are susceptible to motion artifacts from long scanning times. Several novel techniques are potentially feasible for pediatric patients and may be used in the future. Third, the glymphatic dysfunction is associated with a large number of pediatric disorders, although only a few have recently been investigated. In conclusion, research on the pediatric glymphatic system remains an emerging field. The preliminary applications of glymphatic imaging techniques have provided unique insight into the pathological mechanism of pediatric diseases, but mainly limited in visualization of enlarged perivascular spaces and morphological measurements on CSF volumes. More in-depth studies on glymphatic functions are required to improve our understanding of the mechanisms underlying brain development and pediatric diseases. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Encéfalo , Sistema Glinfático , Humanos , Niño , Encéfalo/diagnóstico por imagen , Sistema Glinfático/diagnóstico por imagen , Sistema Linfático , Imagen por Resonancia Magnética/métodos , Medios de Contraste
6.
Magn Reson Imaging ; 105: 92-99, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37939974

RESUMEN

OBJECTIVE: Cerebral venous oxygenation (Yv) is a key parameter for the brain's oxygen utilization and has been suggested to be a valuable biomarker in various brain diseases including hypoxic ischemic encephalopathy in neonates and Alzheimer's disease in older adults. T2-Relaxation-Under-Spin-Tagging (TRUST) MRI is a widely used technique to measure global Yv level and has been validated against gold-standard PET. However, subject motion during TRUST MRI scan can introduce considerable errors in Yv quantification, especially for noncompliant subjects. The aim of this study was to develop an Automatic Rejection based on Tissue Signal (ARTS) algorithm for automatic detection and exclusion of motion-contaminated images to improve the precision of Yv quantification. METHODS: TRUST MRI data were collected from a neonatal cohort (N = 37, 16 females, gestational age = 39.12 ± 1.11 weeks, postnatal age = 1.89 ± 0.74 days) and an older adult cohort (N = 223, 134 females, age = 68.02 ± 9.01 years). Manual identification of motion-corrupted images was conducted for both cohorts to serve as a gold-standard. 9.3% of the images in the neonatal datasets and 0.4% of the images in the older adult datasets were manually identified as motion-contaminated. The ARTS algorithm was trained using the neonatal datasets. TRUST Yv values, as well as the estimation uncertainty (ΔR2) and test-retest coefficient-of-variation (CoV) of Yv, were calculated with and without ARTS motion exclusion. The ARTS algorithm was tested on datasets of older adults: first on the original adult datasets with little motion, and then on simulated adult datasets where the percentage of motion-corrupted images matched that of the neonatal datasets. RESULTS: In the neonatal datasets, the ARTS algorithm exhibited a sensitivity of 0.95 and a specificity of 0.97 in detecting motion-contaminated images. Compared to no motion exclusion, ARTS significantly reduced the ΔR2 (median = 3.68 Hz vs. 4.89 Hz, P = 0.0002) and CoV (median = 2.57% vs. 6.87%, P = 0.0005) of Yv measurements. In the original older adult datasets, the sensitivity and specificity of ARTS were 0.70 and 1.00, respectively. In the simulated adult datasets, ARTS demonstrated a sensitivity of 0.91 and a specificity of 1.00. Additionally, ARTS significantly reduced the ΔR2 compared to no motion exclusion (median = 2.15 Hz vs. 3.54 Hz, P < 0.0001). CONCLUSION: ARTS can improve the reliability of Yv estimation in noncompliant subjects, which may enhance the utility of Yv as a biomarker for brain diseases.


Asunto(s)
Enfermedad de Alzheimer , Encéfalo , Femenino , Recién Nacido , Humanos , Anciano , Lactante , Preescolar , Persona de Mediana Edad , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Oxígeno , Imagen por Resonancia Magnética/métodos , Biomarcadores
7.
NeuroImmune Pharm Ther ; 2(4): 333-338, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38058998

RESUMEN

Objectives: Coronavirus disease 2019 (COVID-19) results in severe inflammation at the acute stage. Chronic neuroinflammation and abnormal immunological response have been suggested to be the contributors to neuro-long-COVID, but direct evidence has been scarce. This study aims to determine the integrity of the blood-brain barrier (BBB) in COVID-19 intensive care unit (ICU) survivors using a novel MRI technique. Methods: COVID-19 ICU survivors (n=7) and age and sex-matched control participants (n=17) were recruited from June 2021 to March 2023. None of the control participants were hospitalized due to COVID-19 infection. The COVID-19 ICU survivors were studied at 98.6 ± 14.9 days after their discharge from ICU. A non-invasive MRI technique was used to assess the BBB permeability to water molecules, in terms of permeability surface area-product (PS) in the units of mL/100 g/min. Results: PS was significantly higher in COVID-19 ICU survivors (p=0.038) when compared to the controls, with values of 153.1 ± 20.9 mL/100 g/min and 132.5 ± 20.7 mL/100 g/min, respectively. In contrast, there were no significant differences in whole-brain cerebral blood flow (p=0.649) or brain volume (p=0.471) between the groups. Conclusions: There is preliminary evidence of a chronic BBB breakdown in COVID-19 survivors who had a severe acute infection, suggesting a plausible contributor to neurological long-COVID symptoms.

8.
Exploration (Beijing) ; 3(4): 20220149, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37933236

RESUMEN

An ideal implant needs to have the ability to coordinate the foreign body response and tissue regeneration. Here, Hydrogenated-silicon nanosheets (H-Si NSs) with favorable biodegradability are integrated and functionalized into a ß-tricalcium phosphate scaffold (H-Si TCP) for bone defect healing. H-Si TCP can greatly improve bone regeneration through osteoimmunomodulation-guided biodegradation in vivo. The spatiotemporal regulation of degradation products replenishes sufficient nutrients step by step for the entire process of bone repair. Extracellular and intracellular reactive oxygen species (ROS) are first downregulated by reaction with H-Si NSs, followed by marked M2 polarization, remodeling the micro-environment timely for immune-bone regeneration. The release of primary reaction products awakened bone marrow mesenchymal stem cells (BMSCs), which are converted into osteoblasts anchored on scaffolds. Subsequently, biomineralization is promoted by the final degradation products. The intrinsic ROS-responsive, immunoregulatory, and osteo-promotive capability of 2D H-Si NSs makes such composite H-Si TCP scaffold a highly potential alternative for the treatment of critical bone defect.

9.
AJNR Am J Neuroradiol ; 44(10): 1224-1230, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37709354

RESUMEN

BACKGROUND AND PURPOSE: Neonatal hypocalcemia is the most common metabolic disorder, and whether asymptomatic disease should be treated with calcium supplements remains controversial. We aimed to quantify neonatal hypocalcemia's global CBF and cerebral metabolic rate of oxygen (CMRO2) using physiologic MR imaging and elucidate the pathophysiologic vulnerabilities of neonatal hypocalcemia. MATERIALS AND METHODS: A total of 37 consecutive patients with neonatal hypocalcemia were enrolled. They were further divided into subgroups with and without structural MR imaging abnormalities, denoted as neonatal hypocalcemia-a (n = 24) and neonatal hypocalcemia-n (n = 13). Nineteen healthy neonates were enrolled as a control group. Brain physiologic parameters determined using phase-contrast MR imaging, T2-relaxation-under-spin-tagging MR imaging, and brain volume were compared between patients with neonatal hypocalcemia (their subgroups) and controls. Predictors for neonatal hypocalcemia-related brain injuries were identified using multivariate logistic regression analysis and expressed as ORs with 95% CIs. RESULTS: Patients with neonatal hypocalcemia showed significantly lower CBF and CMRO2 compared with controls. Furthermore, the neonatal hypocalcemia-a subset (versus controls or neonatal hypocalcemia-n) had significantly lower CBF and CMRO2. There was no obvious difference in CBF and CMRO2 between the neonatal hypocalcemia-n subset and controls. CBF and CMRO2 were independently associated with neonatal hypocalcemia. The ORs were 0.80 (95% CI, 0.65-0.99) and 0.97 (95% CI, 0.89-1.05) for CBF and CMRO2, respectively. CONCLUSIONS: Neonatal hypocalcemia with structural damage may exhibit lower hemodynamics and cerebral metabolism. CBF may be useful in assessing the need for calcium supplementation in asymptomatic neonatal hypocalcemia to prevent brain injury.

11.
Zookeys ; 1165: 17-42, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37292579

RESUMEN

Six species of the family Corinnidae Karsch, 1880 are described from China and Vietnam. Fengzhengen. nov. is erected to accommodate F.menglasp. nov. (♂♀) from China; Penggen. nov. is erected to accommodate P.birmanicus (Thorell, 1897), comb. nov., P.borneensis (Yamasaki, 2017), comb. nov. and P.taprobanicus (Simon, 1897), comb. nov., transferred from Sphecotypus O. Pickard-Cambridge, 1895. Further new species described include Allomedmassatamdaosp. nov. (♂), Echinaxbaishasp. nov. (♂), Medmassalingshuisp. nov. (♂), and Spinirtashaoguansp. nov. (♂). The male of P.birmanicus is described for the first time.

12.
NMR Biomed ; 36(10): e4990, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37315951

RESUMEN

Cerebral venous oxygenation (Yv ) is a valuable biomarker for a variety of brain diseases. T2 relaxation under spin tagging (TRUST) MRI is a widely used method for Yv quantification. In this work, there were two main objectives. The first was to evaluate the reproducibility of TRUST Yv measurements across MRI scanners from different vendors. The second was to examine the correlation between Yv and end-tidal CO2 (EtCO2 ) in a multisite, multivendor setting and determine the usefulness of this correlation to account for variations in Yv caused by normal variations and physiological fluctuations. Standardized TRUST pulse sequences were implemented on three scanners from major MRI vendors (GE, Siemens, Philips). These scanners were located at two research institutions. Ten healthy subjects were scanned. On each scanner, the subject underwent two scan sessions, each of which included three TRUST scans, to evaluate the intrasession and intersession reproducibility of Yv . Each scanner was also equipped with a capnograph device to record the EtCO2 of the subject during the MRI scan. We found no significant bias in Yv measurements across the three scanners (P = 0.18). The measured Yv values on the three scanners were also strongly correlated with each other (intraclass correlation coefficients > 0.85, P < 0.001). The intrasession and intersession coefficients of variation of Yv were less than 4% and showed no significant difference among the scanners. In addition, our results revealed that (1) within the same subject, Yv increased with EtCO2 at a rate of 1.24 ± 0.17%/mmHg (P < 0.0001), and (2) across different subjects, individuals with a higher EtCO2 had a higher Yv , at a rate of 0.94 ± 0.36%/mmHg (P = 0.01). These results suggest that (1) the standardized TRUST sequences had similar accuracies and reproducibilities for the quantification of Yv across the scanners, and (2) recording of EtCO2 may be a useful complement to Yv measurement to account for CO2 -related physiological fluctuations in Yv in multisite, multivendor studies.


Asunto(s)
Encefalopatías , Dióxido de Carbono , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Voluntarios Sanos , Encéfalo/diagnóstico por imagen
13.
NPJ Digit Med ; 6(1): 116, 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37344684

RESUMEN

Cerebrovascular disease is a leading cause of death globally. Prevention and early intervention are known to be the most effective forms of its management. Non-invasive imaging methods hold great promises for early stratification, but at present lack the sensitivity for personalized prognosis. Resting-state functional magnetic resonance imaging (rs-fMRI), a powerful tool previously used for mapping neural activity, is available in most hospitals. Here we show that rs-fMRI can be used to map cerebral hemodynamic function and delineate impairment. By exploiting time variations in breathing pattern during rs-fMRI, deep learning enables reproducible mapping of cerebrovascular reactivity (CVR) and bolus arrival time (BAT) of the human brain using resting-state CO2 fluctuations as a natural "contrast media". The deep-learning network is trained with CVR and BAT maps obtained with a reference method of CO2-inhalation MRI, which includes data from young and older healthy subjects and patients with Moyamoya disease and brain tumors. We demonstrate the performance of deep-learning cerebrovascular mapping in the detection of vascular abnormalities, evaluation of revascularization effects, and vascular alterations in normal aging. In addition, cerebrovascular maps obtained with the proposed method exhibit excellent reproducibility in both healthy volunteers and stroke patients. Deep-learning resting-state vascular imaging has the potential to become a useful tool in clinical cerebrovascular imaging.

14.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(4): 443-446, 2023 Apr 15.
Artículo en Chino | MEDLINE | ID: mdl-37070311

RESUMEN

Objective: To investigate the feasibility and effectiveness of absorbable anchor combined with Kirschner wire fixation in the reconstruction of extension function of old mallet finger. Methods: Between January 2020 and January 2022, 23 cases of old mallet fingers were treated. There were 17 males and 6 females with an average age of 42 years (range, 18-70 years). The cause of injury included sports impact injury in 12 cases, sprain in 9 cases, and previous cut injury in 2 cases. The affected finger included index finger in 4 cases, middle finger in 5 cases, ring finger in 9 cases, and little finger in 5 cases. There were 18 patients of tendinous mallet fingers (Doyle type Ⅰ), 5 patients were only small bone fragments avulsion (Wehbe type ⅠA). The time from injury to operation was 45-120 days, with an average of 67 days. The patients were treated with Kirschner wire to fix the distal interphalangeal joint in a mild back extension position after joint release. The insertion of extensor tendon was reconstructed and fixed with absorbable anchors. After 6 weeks, the Kirschner wire was removed, and the patients started joint flexion and extension training. Results: The postoperative follow-up ranged from 4 to 24 months (mean, 9 months). The wounds healed by first intention without complications such as skin necrosis, wound infection, and nail deformity. The distal interphalangeal joint was not stiff, the joint space was good, and there was no complication such as pain and osteoarthritis. At last follow-up, according to Crawford function evaluation standard, 12 cases were excellent, 9 cases were good, 2 cases were fair, and the good and excellent rate was 91.3%. Conclusion: Absorbable anchor combined with Kirschner wire fixation can be used to reconstruct the extension function of old mallet finger, which has the advantages of simple operation and less complications.


Asunto(s)
Traumatismos de los Dedos , Fracturas Óseas , Traumatismos de los Tendones , Masculino , Femenino , Humanos , Adulto , Hilos Ortopédicos , Fijación Interna de Fracturas , Traumatismos de los Dedos/cirugía , Fracturas Óseas/cirugía , Traumatismos de los Tendones/cirugía , Dedos , Resultado del Tratamiento , Articulaciones de los Dedos/cirugía
15.
J Alzheimers Dis ; 92(1): 323-339, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36744337

RESUMEN

BACKGROUND: Alzheimer's disease (AD) frequently co-occurs with other brain pathologies. Recent studies suggest there may be a mechanistic link between AD and small vessel cerebrovascular disease (CVD), as opposed to simply the overlap of two disorders. OBJECTIVE: We investigated the cross-sectional relationship between white matter hyperintensity (WMH) volumes (markers of CVD) and cerebrospinal fluid (CSF) biomarkers of AD. METHODS: WMH volumes were assessed globally and regionally (i.e., frontal, parietal, temporal, occipital, and limbic). CSF AD biomarkers (i.e., Aß 40, Aß 42, Aß 42/Aß 40 ratio, phosphorylated tau-181 [p-tau181], and total tau [t-tau]) were measured among 152 non-demented individuals (134 cognitively unimpaired and 18 with mild cognitive impairment (MCI)). RESULTS: Linear regression models showed that among all subjects, higher temporal WHM volumes were associated with AD biomarkers (higher levels of p-tau181, t-tau, and Aß 40), particularly among APOE ɛ 4 carriers (independent of Aß 42 levels). Higher vascular risk scores were associated with greater parietal and frontal WMH volumes (independent of CSF AD biomarker levels). Among subjects with MCI only, parietal WMH volumes were associated with a lower level of Aß 42/Aß 40. In addition, there was an association between higher global WMH volumes and higher CSF t-tau levels among younger participants versus older ones (∼<65 versus 65+ years), independent of Aß 42/Aß 40 and p-tau181. CONCLUSION: These findings suggest that although WMH are primarily related to systemic vascular risk and neurodegeneration (i.e., t-tau), AD-specific pathways may contribute to the formation of WMH in a regionally-specific manner, with neurofibrillary tangles (i.e., p-tau) playing a role in temporal WMHs and amyloid (i.e., Aß 42/Aß 40) in parietal WMHs.


Asunto(s)
Enfermedad de Alzheimer , Enfermedades de los Pequeños Vasos Cerebrales , Disfunción Cognitiva , Sustancia Blanca , Humanos , Anciano , Enfermedad de Alzheimer/patología , Sustancia Blanca/patología , Péptidos beta-Amiloides/metabolismo , Imagen por Resonancia Magnética , Disfunción Cognitiva/patología , Cognición , Proteínas tau/metabolismo , Enfermedades de los Pequeños Vasos Cerebrales/complicaciones , Biomarcadores/líquido cefalorraquídeo
16.
Proc Biol Sci ; 290(1993): 20222094, 2023 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-36809803

RESUMEN

The arms race between brood parasites and their hosts provides a classic model to study coevolution. Hosts often reject the parasitic egg, and brood parasites should therefore select host nests in which the colour of the eggs best matches that of their own. Although this hypothesis has received some support, direct experimental evidence is still lacking. Here, we report on a study of Daurian redstarts, which show a distinct egg-colour dimorphism, with females laying either blue or pink eggs. Redstarts are often parasitized by common cuckoos, which lay light blue eggs. First, we showed that cuckoo eggs were more similar in spectral reflectance to the blue than to the pink redstart egg morph. Second, we report that the natural parasitism rate was higher in blue than in pink host clutches. Third, we performed a field experiment in which we presented a dummy clutch of each colour morph adjacent to active redstart nests. In this set-up, cuckoos almost always chose to parasitize a blue clutch. Our results demonstrate that cuckoos actively choose redstart nests in which the egg colour matches the colour of their own eggs. Our study thus provides direct experimental evidence in support of the egg matching hypothesis.


Asunto(s)
Parásitos , Passeriformes , Animales , Femenino , Comportamiento de Nidificación , Óvulo
17.
Neuroimage ; 268: 119870, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36640948

RESUMEN

Blood-brain barrier (BBB) plays a critical role in protecting the brain from toxins and pathogens. However, in vivo tools to assess BBB permeability are scarce and often require the use of exogenous contrast agents. In this study, we aimed to develop a non-contrast arterial-spin-labeling (ASL) based MRI technique to estimate BBB permeability to water in mice. By determining the relative fraction of labeled water spins that were exchanged into the brain tissue as opposed to those that remained in the cerebral veins, we estimated indices of global BBB permeability to water including water extraction fraction (E) and permeability surface-area product (PS). First, using multiple post-labeling delay ASL experiments, we estimated the bolus arrival time (BAT) of the labeled spins to reach the great vein of Galen (VG) to be 691.2 ± 14.5 ms (N = 5). Next, we investigated the dependence of the VG ASL signal on labeling duration and identified an optimal imaging protocol with a labeling duration of 1200 ms and a PLD of 100 ms. Quantitative E and PS values in wild-type mice were found to be 59.9 ± 3.2% and 260.9 ± 18.9 ml/100 g/min, respectively. In contrast, mice with Huntington's disease (HD) revealed a significantly higher E (69.7 ± 2.4%, P = 0.026) and PS (318.1 ± 17.1 ml/100 g/min, P = 0.040), suggesting BBB breakdown in this mouse model. Reproducibility studies revealed a coefficient-of-variation (CoV) of 4.9 ± 1.7% and 6.1 ± 1.2% for E and PS, respectively. The proposed method may open new avenues for preclinical research on pathophysiological mechanisms of brain diseases and therapeutic trials in animal models.


Asunto(s)
Barrera Hematoencefálica , Venas Cerebrales , Ratones , Animales , Barrera Hematoencefálica/diagnóstico por imagen , Barrera Hematoencefálica/fisiología , Venas Cerebrales/diagnóstico por imagen , Marcadores de Spin , Agua , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Permeabilidad , Circulación Cerebrovascular/fisiología
18.
Food Chem ; 412: 135554, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-36708671

RESUMEN

Tetracycline antibiotics (TCs), one of the important antibiotic groups, have been widely used in human and veterinary medicines. Their residues in foodstuff, soil and sewage have caused serious threats to food safety, ecological environment and human health. Here, we reviewed the potential harms of TCs residues to foodstuff, environment and human beings, discussed the luminescence and aptamer sensors based analytical determination, adsorptive removal, and degradation strategies of TCs residues from a recent 5-year period. The advantages and intrinsic limitations of these strategies have been compared and discussed, the potential challenges and opportunities in TCs residues degradation have also been deliberated and explored.


Asunto(s)
Compuestos Heterocíclicos , Contaminantes del Suelo , Humanos , Luminiscencia , Antibacterianos/química , Contaminantes del Suelo/análisis , Inocuidad de los Alimentos , Tetraciclinas/análisis , Tetraciclina/química
19.
Neuroimage ; 266: 119829, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36565971

RESUMEN

The medial temporal lobe (MTL) is a key area implicated in many brain diseases, such as Alzheimer's disease. As a functional biomarker, the oxygen extraction fraction (OEF) of MTL may be more sensitive than structural atrophy of MTL, especially at the early stages of diseases. However, there is a lack of non-invasive techniques to measure MTL-OEF in humans. The goal of this work is to develop an MRI technique to assess MTL-OEF in a clinically practical time without using contrast agents. The proposed method measures venous oxygenation (Yv) in the basal veins of Rosenthal (BVs), which are the major draining veins of the MTL. MTL-OEF can then be estimated as the arterio-venous difference in oxygenation. We developed an MRI sequence, dubbed arterial-suppressed accelerated T2-relaxation-under-phase-contrast (AS-aTRUPC), to quantify the blood T2 of the BVs, which was then converted to Yv through a well-established calibration model. MTL-OEF was calculated as (Ya-Yv)/Ya × 100%, where Ya was the arterial oxygenation. The feasibility of AS-aTRUPC to quantify MTL-OEF was evaluated in 16 healthy adults. The sensitivity of AS-aTRUPC in detecting OEF changes was assessed by a caffeine ingestion (200 mg) challenge. For comparison, T2-relaxation-under-spin-tagging (TRUST) MRI, which is a widely used global OEF technique, was also acquired. The dependence of MTL-OEF on age was examined by including another seven healthy elderly subjects. The results showed that in healthy adults, MTL-OEF of the left and right hemispheres were correlated (P=0.005). MTL-OEF was measured to be 23.9±3.6% (mean±standard deviation) and was significantly lower (P<0.0001) than the OEF of 33.3±2.9% measured in superior sagittal sinus (SSS). After caffeine ingestion, there was an absolute percentage increase of 9.1±4.0% in MTL-OEF. Additionally, OEF in SSS measured with AS-aTRUPC showed a strong correlation with TRUST OEF (intra-class correlation coefficient=0.94 with 95% confidence interval [0.91, 0.96]), with no significant bias (P=0.12). MTL-OEF was found to increase with age (MTL-OEF=20.997+0.100 × age; P=0.02). In conclusion, AS-aTRUPC MRI provides non-invasive assessments of MTL-OEF and may facilitate future clinical applications of MTL-OEF as a disease biomarker.


Asunto(s)
Venas Cerebrales , Oxígeno , Adulto , Humanos , Anciano , Cafeína , Encéfalo/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Venas Cerebrales/diagnóstico por imagen , Consumo de Oxígeno , Circulación Cerebrovascular
20.
Alzheimers Dement ; 19(2): 569-577, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35791732

RESUMEN

INTRODUCTION: Oxygen extraction fraction (OEF) reflects the balance between oxygen delivery and consumption. We longitudinally measured OEF in older adults to examine the relationship with markers of Alzheimer's disease (AD) and vascular pathology. METHODS: One hundred thirty-seven participants were studied at two time-points at an interval of 2.16 years. OEF was measured using T2 -relaxation-under-spin-tagging (TRUST) magnetic resonance imaging (MRI). The association between OEF and vascular risks, white matter hyperintensities (WMH), cerebrospinal fluid (CSF) measures of amyloid beta (Aß), total tau (t-tau), and phosphorylated tau 181 (p-tau181) was examined. RESULTS: OEF increased from baseline to follow-up. The increase in OEF was more prominent in individuals with high vascular risks compared to those with low vascular risks, and was associated with progression of vascular risks and the growth in WMH volume. OEF change was not related to CSF markers of AD pathology or their progression. DISCUSSION: Longitudinal OEF change in older adults is primarily related to vascular pathology.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Anciano , Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/metabolismo , Oxígeno , Disfunción Cognitiva/patología , Encéfalo/patología , Proteínas tau/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...